저자(한글) |
유희정,김정식,이정순,문동민,이진복,김종호,김상훈,이일용,기상청 기후변화감시센터,기상청 기후정책과,한국표준과학연구원 대기환경표준센터,한국표준과학연구원 대기환경표준센터,한국표준과학연구원 대기환경표준센터,한서대학교 환경공학과,기상청 기후변화감시센터,기상청 기후변화감시센터 |
초록 |
Korea Global Atmosphere Watch Center (KGAWC), which is located in Anmyeondo and, belongs to the Korea Meteorological Administration (KMA), measures sulfur hexafluoride ($SF_6$) in every hour since 2007. In this study, $SF_6$ observed in 2007 are discussed. A gas chromatograph-electron capture detector (GC-ECD) with pre-cooled device is applied during the observation, and produced data are qualified by means of periodic calibration with $SF_6$ standard gas made by Korea Research Institute of Standard and Science (KRISS). $SF_6$ has been greatly paid attention since Kyoto protocol because of its high global warming potential(GWP) with 22,200 times of $CO_2$ in the period of 100 years. It is a man-made compound and has been usually used for gas insulation since 1970s and for etching process in the information technology-based industry since 1990. Average mixing ratio of $SF_6$ in 2007 was 6.65 pmol/mol at Anmyeondo. According to the GAW report published in 2008, average mixing ratio of $SF_6$ in the atmosphere is continuously growing. At present, the average mixing ratio of $SF_6$ in the atmosphere is known to be approximately 6.25 pmol/mol at global observatory. $SF_6$ value in Anmyeondo shows 0.40 pmol/mol greater than that of the Mauna Loa observatory in 2007. |